The Flow Lab's legacy FACSAria is finally getting its fluidics upgrade today. The process takes about 3 days, so I'll give you some updates via photos. Day 1 was basically demo day, and the pic displayed here is the Fluidics area inside which has been totally ripped out. It looks a bit messy now, but the new system is much more stream-lined than the old. For those of you not familiar with the benefits of the fluidics upgrade, I'll give you a quick run-down and a bit of history. 1st the history. Sorters, for years have used a very simple process for driving fluidics; fill a tank with PBS, pressurize the tank at constant pressure, which causes the fluid to move through the system at a constant velocity, thereby giving a stable droplet break-off pattern. Enter BD and their quest to put a sorter on every researcher's desk. BD developed a fluidics system which was marketed as a "bench-top" sorter which could be run by anyone. Everything is automated, cleaning, sterilizing, running, monitoring, etc... In attempting to make this "easy-to-use" sorter, they created a service nightmare. There were so many valves and switches and pumps put in to do the simple job of moving PBS from a tank to a flow cell that at any given point, one of them was not working properly. Additionally, with all the valves and switches and automation came many small pieces of tubing and hangouts for bugs and bacteria. This created a situation where we had to jump through hoops trying to keep the sorter clean. Other sorters, like the MoFlo still had the classic fluidics system and, at least in our hands, had almost zero fluidics problems over about a 10 year period, and very few contamination issues with little effort. After a few years of complaints and retooling, BD releases the FACSAria II, and guess what? They got rid of a ton of valves, switches, hideouts, and once again went back to a simplified, robust fluidics system. It still has a few bells and whistles, but certainly not as grotesquely over-engineered as the Aria I. Will it withstand the onslaught of abuse only a core facility like ours can dole out? Only time will tell. Regardless, you'll hear about it here, so stay tuned.
A Blog about the world of Image and Flow Cytometry. Coming to you from the core facility at the University of Chicago
Tuesday, February 3, 2009
Aria to Aria II upgrade...Day 1
The Flow Lab's legacy FACSAria is finally getting its fluidics upgrade today. The process takes about 3 days, so I'll give you some updates via photos. Day 1 was basically demo day, and the pic displayed here is the Fluidics area inside which has been totally ripped out. It looks a bit messy now, but the new system is much more stream-lined than the old. For those of you not familiar with the benefits of the fluidics upgrade, I'll give you a quick run-down and a bit of history. 1st the history. Sorters, for years have used a very simple process for driving fluidics; fill a tank with PBS, pressurize the tank at constant pressure, which causes the fluid to move through the system at a constant velocity, thereby giving a stable droplet break-off pattern. Enter BD and their quest to put a sorter on every researcher's desk. BD developed a fluidics system which was marketed as a "bench-top" sorter which could be run by anyone. Everything is automated, cleaning, sterilizing, running, monitoring, etc... In attempting to make this "easy-to-use" sorter, they created a service nightmare. There were so many valves and switches and pumps put in to do the simple job of moving PBS from a tank to a flow cell that at any given point, one of them was not working properly. Additionally, with all the valves and switches and automation came many small pieces of tubing and hangouts for bugs and bacteria. This created a situation where we had to jump through hoops trying to keep the sorter clean. Other sorters, like the MoFlo still had the classic fluidics system and, at least in our hands, had almost zero fluidics problems over about a 10 year period, and very few contamination issues with little effort. After a few years of complaints and retooling, BD releases the FACSAria II, and guess what? They got rid of a ton of valves, switches, hideouts, and once again went back to a simplified, robust fluidics system. It still has a few bells and whistles, but certainly not as grotesquely over-engineered as the Aria I. Will it withstand the onslaught of abuse only a core facility like ours can dole out? Only time will tell. Regardless, you'll hear about it here, so stay tuned.
Tuesday, January 6, 2009
How to choose - Part I
I am constantly reviewing new flow cytometry related technology, and I must admit, it's a pretty fun part of the job. So, over the years I think I've developed some strategies for choosing the proper piece of equipment which I will attempt to share in this "How to Choose" series. The Flow Cytometry Facility was recently awarded a Shared Instrumentation Grant from the NIH to purchase the LSRII it has been leasing for the past 8 months (see previous post for details). In approaching the original plan to acquire a new high-end analyzer, I went through this time-consuming process of evaluating multiple pieces of equipment in order to decide which one to get. Therefore, I will attempt to outline some of the key aspects which can hopefully translate to technology and equipment outside of flow cytometry. In general, the steps for choosing the proper instrument include, 1. Query your user base, 2. Establish selection criteria, 3. Research available technologies, 4. Match available technology with criteria, 5. Weigh non-technical aspects of ownership (e.g. Service, Infrastructure Necessities, Space, etc.), and 6. Test the instrument with real samples. I've gone through this process for equipment as complex as cell sorters, and as simple as incubators, and every time I feel the proper decision was made. The next few postings will detail the specifics of each of these 6 steps, so be sure to check back soon for an update.
Monday, January 5, 2009
Flow Cytometry Facility awarded NIH SIG
The Flow Cytometry Facility is pleased to announce that we have been awarded a Shared Instrumentation Grant from the NIH, which will be used to pay off the LSRII-Blue we have been leasing since April 2008. The facility recognized the necessity for such a high-end benchtop analyzer that we proceeded to lease the LSRII while resubmitting the grant proposal for the instrument. Needless to say we are very happy with the outcome of this proposal, and with the performance of the LSRII thus far. When publishing data using the facility's LSRII, you may acknowledge the facility as well as the SIG grant number for this instrument, 1S10RR24570-01A1.
Monday, December 22, 2008
"Lasers"

Do you like Star Wars? I do. I'm not one of those freaky, dress-up like Chewbacca fans, and talk like yoda, I do not, but what I really like about Star Wars are the lasers. It just seems like such a practical way to shoot things. No need to carry along a bunch of ammunition, all you need is your trusty multi-KiloWatt laser. Another benefit is that light travels, well, at the speed of light, much faster than a speeding bullet or a falling bomb. Lasers are used all over the place, most-notably for me, Flow Cytometry and Microscopy, but now it seems like the vision of Star Wars may be closer than ever. Darpa (The advanced research division of the Department of Defense) has been investigating weapons-grade lasers for some time, but with the use of some newer technologies, there may actually be a viable option. HELLADS, or High Energy Liquid Laser Area Defense System, a laser system developed by Textron, is getting some big government bucks to design and test a 150kW Laser Weapon System that could be carried on a Fighter Jet and be used to shoot down missiles. So, what's so special about the laser? It seems this laser system is using a series of thin ceramic slabs, bathed in rapidly circulating coolant to achieve a high power output while maintaining a non-destructive temperature load. These so-called slab lasers are attempting to tackle a long-standing problem with lasers, what to do with waste heat. If successfully employed, these types of technologies may trickle their way down to us lowly folks in the flow cytometry world, and I may actually be able to realize my goal of a centralized laser depot with a bunch of fiber-optic cables extending out of it. I've already got a name for it...Medussa! If you have a high enough laser source, you could split that beam a bunch of times, and using fiber optic cables, bring the light to any number of instruments using a "plug-n-play" connection scheme. Some day...
Thursday, December 4, 2008
Flow Basics is Back! and slimmer than ever!

That's right folks, by popular demand, we're reintroducing a legend, Flow Basics. But, Wow Flow Basics, have you been working out? I mean, you're about half the size as the last time I saw you. You've gotta be down to, what, like 5MB or something? Not only is Flow Basics back, but it's leaner and meaner than ever, well, not really meaner, but definitely leaner. We've trimmed a bunch of the slides while still focussing on the most important aspects of basic flow cytometry theory and instrument usage. We will once again be making this a mandatory requirement for new flow cytometer trainees, but anyone who did not attend the original flow basics, will want to attend one of these training sessions. To make this process easier, we will be offering the course more frequently especially in the next coming months. Once the initial rush is over, we will over the course every other week as new users are being trained. We're also putting the course schedule on the facility's Online Instrument Scheduler, so now, you'll know exactly when the next class will be offered, as well as have an opportunity to sign up whenever is convenient for you. Although the Online Scheduler offers convenience and flexibility, the sign-up process has a few steps to it that may make it somewhat challenging the 1st time you attempt. So, we also made a little video demonstration on how to sign-up for training. We've embedded the video here for you to watch. Classes start 12/10/08, so check the online scheduler for more dates and to sign up.
Wednesday, November 26, 2008
561nm Laser Demo - MoFlo
We will be having a demo of a 200mW 561nm solid state laser on our MoFlo December 2nd and 3rd, 2008. Beckman Coulter will be in to install the laser as well as a detector block so we can assess the utility of such a laser for our sorting applications. The major benefit of this laser will be the ability to excite fluorochromes not normally excited at 488nm or 633nm, such as mCherry, RFP variants, and more. Other benefits of interest will be the stronger excitation of PE and PE-Tandems as well as the lack of spillover of blue excited fluorochromes like FITC and PerCPCy5.5 into PE channels. This will effectively increase the resolution of dimly stained populations, especially when identifying cells which are double positive for FITC and PE. We have a few scheduled demos of the laser with users of the facility, so if you'd like to see the laser in action, give us a call to find out what time we'll be running samples on the 2nd and 3rd. Or, just drop by on either day to take a look at the setup.
Monday, November 3, 2008
New - Flow Data Flickr Image Pool
Why not stop over at the UCFlow Image Pool on Flickr (www.flickr.com) and check out some of the photos of data, instruments, and other things of interest. Or, better yet, why not send an image of your own to the flickr pool. All we ask is that it be flow cytometry related. If you want to send your image, simply compose an email to whose60which@photos.flickr.com. The Subject line of the email will be the photo's title, and the body of the email will be a description of the photo (make sure to remove your signature so it doesn't become part of the description). Then just attach the image, and send it along. It will be posted to the flickr pool, and randomly displayed on the facility's home page, http://ucflow.uchicago.edu